SKU | HI2040-02 |
Product Name | Edge Multiparameter DO Meter - HI2040 |
Stock Status Message | Ships within 24 hours (In Business Days) |
Quote Required | No |
pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, -/+ 1000 mV |
pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
pH Accuracy | -/+ 0.002 pH, -/+ 0.01 pH, -/+ 0.2 mV |
pH Calibration | Automatic, up to 3 points (5 points) calibration, 5 standard (7 standard) buffers available (1.68, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45) and 2 custom buffers |
pH Temperature Compensation | ATC |
pH CAL Check (electrode diagnostics) | glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time |
EC Range | 0.00 to 29.99 uS/cm, 3.00 to 29.99 uS/cm, 30.0 to 299.9 uS/cm, 300 to 2999 u S/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity |
EC Resolution | 0.01 u S/cm, 00.1 u S/cm, 0.01 u S/cm, 0.01 mS/cm, 00.1 mS/cm |
EC Accuracy | -/+ 1% of reading (-/+ 0.05 u S/cm or 1 digit, whichever is greater) |
EC Calibration | 1 Cell Factor calibration; 6 standards available |
TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS (with 0.80 factor) |
TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
TDS Accuracy | -/+ 1% of reading (-/+ 0.03 ppm or 1 digit, whichever is greater) |
TDS Calibration | through EC calibration |
EC/TDS Temperature Compensation | Automatic -5 to 100 degree C (23 to 212 degree F); NoTC - can be selected to measure absolute conductivity |
Temperature Correction Coefficient | 0.00 to 6.00% / degree C (for EC and TDS only). Default value is 1.90% / degree C |
EC to TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
Salinity (% NaCl) Range | 0.0 to 400.0% NaCl |
Salinity (% NaCl) Resolution | 0.1% NaCl |
Salinity (% NaCl) Accuracy | -/+ 1% of reading (25degree C/77degree F) |
Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
Salinity (PSU) Range | 2.00 to 42.00 PSU |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | -/+ 1% of reading (25degree C/77degree F) |
Salinity (PSU) Calibration | through EC calibration |
Salinity Range | 0.0 to 80.0 g/L |
Salinity Resolution (ppt) | 0.01 g/L |
Salinity Accuracy (ppt) | -/+ 1% of reading (25degree C/77degree F) |
Salinity Calibration (ppt) | through EC calibration |
Dissolved Oxygen Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
Dissolved Oxygen Resolution | 0.01 ppm, 0.1% saturation |
Dissolved Oxygen Accuracy | -/+ 1 digit, -/+ 1.5% of reading |
Dissolved Oxygen Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
Dissolved Oxygen Temperature Compensation | ATC |
Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
Temperature Range | -20.0 to 120.0 degree C, -4.0 to 248.0 degree F |
Temperature Resolution | 0.1 degree C, 0.1 degree F |
Temperature Accuracy | -/+ 0.5 degree C, -/+ 1.0 degree F |
DO Probe | HI 764080 (included) |
Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging (Max. 600 samples; 100 lots) |
Logging Memory | up to 1000 records |
Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Environment | 0 to 50degree C (32 to 122degree F), RH max 95% non-condensing |
Dimensions | 202 x 140 x 12.7mm (8 x 5.5 x 0.5 inch) |
Weight | 250 g (8.82 oz) |
Ordering Information | HI2040 includes |
Hsn Code | 90278990 |
HANNA EQUIPMENTS INDIA PVT. LTD.